{"id":157,"date":"2025-11-26T07:14:58","date_gmt":"2025-11-26T07:14:58","guid":{"rendered":"https:\/\/chgswabstick.com\/?p=157"},"modified":"2025-11-26T07:14:58","modified_gmt":"2025-11-26T07:14:58","slug":"inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies","status":"publish","type":"post","link":"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/","title":{"rendered":"Inadequate Disinfection with CHG Applicators? 3 Core Reasons and Mitigation Strategies"},"content":{"rendered":"<p class=\"ds-markdown-paragraph\">In clinical practice, the standardized use of CHG applicators is crucial for infection prevention. However, instances of inadequate disinfection often stem from a few easily overlooked details. This article systematically analyzes the core reasons for suboptimal results and provides practical mitigation strategies to help improve the disinfection success rate, intended for quick clinical reference.<\/p>\n<hr \/>\n<p class=\"ds-markdown-paragraph\"><strong>Chlorhexidine Gluconate (CHG) Disinfection Applicators<\/strong><\/p>\n<p class=\"ds-markdown-paragraph\"><strong>Reason 1: Insufficient Dose \u2013 Evaporation of Storage Solution or Low Sponge Absorption<\/strong><br \/>\nEffective disinfection first relies on an adequate volume and accurate concentration of the disinfectant solution.<\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Identifying Signs:<\/strong>\u00a0After opening the package, the sponge head appears dry, shriveled, not sufficiently moist, or the observed liquid level is significantly below 2\/3 of the sponge volume.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Potential Risk:<\/strong>\u00a0An insufficient dose leads to a decrease in the concentration of the active ingredient (chlorhexidine). If the concentration falls below 1.5%, its bactericidal efficacy may decrease by up to 40% (based on internal validation averages), failing to achieve the intended effect.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Mitigation Strategies:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>During Procurement:<\/strong>\u00a0Choose products with individual aluminum foil packaging and check the labeled nominal absorption volume, which should be within the range of 3 mL \u00b1 0.2 mL.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Before Use:<\/strong>\u00a0Gently squeeze the sponge to confirm it is moist without dripping liquid, indicating good condition.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>During Storage:<\/strong>\u00a0Maintain storage environment temperature \u2264 25\u00b0C, relative humidity \u2264 60%, and avoid direct sunlight.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p class=\"ds-markdown-paragraph\"><strong>Reason 2: Non-standardized Operation \u2013 Failure to Allow Drying, Re-wiping, Insufficient Radius<\/strong><br \/>\nEven with a qualified product, non-standardized operation can negate the disinfection effect.<\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Identifying Signs:<\/strong>\u00a0Performing puncture within 30 seconds after application, re-wiping an area that has already dried, or using an insufficient disinfection area with a radius less than 8 cm.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Potential Risk:<\/strong>\u00a0Incomplete drying can lead to chemical phlebitis due to residual alcohol, while the risk of bacterial residue may increase by approximately 0.3%.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Mitigation Strategies:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Core Operational Points:<\/strong>\u00a0Adhere to unidirectional (one-way) wiping. Ensure the disinfection radius is \u2265 8 cm and the vigorous scrubbing time is \u2265 30 seconds.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Critical Waiting Period:<\/strong>\u00a0After application, it must be allowed to air-dry naturally for \u2265 30 seconds. Do not fan the area or touch it with hands during this time.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Final Verification:<\/strong>\u00a0Before puncture, visually confirm that the skin is completely dry.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p class=\"ds-markdown-paragraph\"><strong>Reason 3: Environmental Interference \u2013 High Temperature, High Humidity, Air Pollution<\/strong><br \/>\nImproper storage and usage environments can directly compromise the stability of the disinfectant solution.<\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Identifying Signs:<\/strong>\u00a0Storage room temperature exceeds 40\u00b0C, or water stains\/damage are observed on the aluminum foil packaging.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Potential Risk:<\/strong>\u00a0High temperature and humidity accelerate alcohol evaporation and chlorhexidine precipitation, potentially leading to up to 15% degradation of the active ingredient.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Mitigation Strategies:<\/strong><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Storage &amp; Transportation Assurance:<\/strong>\u00a0During transport and warehousing, using a 2\u20138\u00b0C cold chain is recommended, especially in summer, with added ice packs.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Pre-use Check:<\/strong>\u00a0Always inspect the integrity of the aluminum foil packaging before use. Discard immediately if damaged.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Environmental Monitoring:<\/strong>\u00a0Ensure air quality in the procedure area meets standards, with airborne bacterial counts controlled within \u2264 4 CFU\/plate (5-minute exposure).<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<hr \/>\n<p class=\"ds-markdown-paragraph\"><strong>On-site Quick Verification: 3 Steps to Assess Disinfection Adequacy<\/strong><\/p>\n<p class=\"ds-markdown-paragraph\">When immediate microbiological testing is unavailable, use the following methods for quick verification:<\/p>\n<ol start=\"1\">\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Visual Inspection:<\/strong>\u00a0The disinfected skin should appear uniformly moist without a strong, lingering alcohol odor.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Timing:<\/strong>\u00a0The total time from the start of application to complete drying should be no less than 60 seconds.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Fluorescent Marker (if available):<\/strong>\u00a0Use a dedicated fluorescent marker solution. Observe under a UV lamp; if the coverage area is &lt; 80%, re-disinfection and sampling are required.<\/p>\n<\/li>\n<\/ol>\n<hr \/>\n<p class=\"ds-markdown-paragraph\"><strong>Huachenyang CHG Applicator Troubleshooting Highlights<\/strong><\/p>\n<p class=\"ds-markdown-paragraph\">Addressing the common issues above, Huachenyang has implemented targeted optimizations in product design. Its CHG applicators feature the following troubleshooting highlights:<\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Packaging Barrier:<\/strong>\u00a0Utilizes double-layer aluminum foil with an easy-tear notch design, offering a very low water vapor transmission rate to effectively protect the contents.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Liquid Visibility:<\/strong>\u00a0Unique polyurethane sponge and packaging design provide a real-time viewing window for liquid absorption, allowing quick pre-use verification.<\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong>Traceability:<\/strong>\u00a0Each product has an independent barcode and clear expiration date printed, ensuring precise traceability of any compromised batches.<\/p>\n<\/li>\n<\/ul>\n<hr \/>\n<p class=\"ds-markdown-paragraph\"><strong>Frequently Asked Questions<\/strong><\/p>\n<p class=\"ds-markdown-paragraph\"><strong>Q1: If disinfection seems insufficient, can I reapply?<\/strong><br \/>\n\u2192\u00a0<strong>Strictly prohibited.<\/strong>\u00a0After the first application dries, it forms a protective film on the skin. Reapplying disrupts this film and introduces contamination risk.<\/p>\n<p class=\"ds-markdown-paragraph\"><strong>Q2: How should I handle a puncture site with broken skin?<\/strong><br \/>\n\u2192\u00a0<strong>Do not use the CHG applicator.<\/strong>\u00a0Clean the area with normal saline instead and protect it with sterile gauze.<\/p>\n<p class=\"ds-markdown-paragraph\"><strong>Q3: How long can a single opened applicator be stored?<\/strong><br \/>\n\u2192 This product is for single-use only. It is designed to be used immediately after opening and discarded after use. It must not be reused or stored.<\/p>\n<hr \/>\n<p class=\"ds-markdown-paragraph\"><strong>Important Note:<\/strong>\u00a0This product is a topical skin disinfection device. Correct storage and standardized operation are prerequisites for ensuring disinfection efficacy.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In clinical practice, the standardized use of CHG applicators is crucial for infection prevention. However, instances of inadequate disinfection often stem from a few easily overlooked details. This article systematically analyzes the core reasons for suboptimal results and provides practical mitigation strategies to help improve the disinfection success rate, intended for quick clinical reference. Chlorhexidine [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":163,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[32],"tags":[],"class_list":{"0":"post-157","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","6":"hentry","7":"category-chg-ipa-applicator","9":"post-with-thumbnail","10":"post-with-thumbnail-large"},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.2 (Yoast SEO v26.6) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Inadequate Disinfection with CHG Applicators? 3 Core Reasons and Mitigation Strategies - CHG IPA APPLICATOR<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Inadequate Disinfection with CHG Applicators? 3 Core Reasons and Mitigation Strategies\" \/>\n<meta property=\"og:description\" content=\"In clinical practice, the standardized use of CHG applicators is crucial for infection prevention. However, instances of inadequate disinfection often stem from a few easily overlooked details. This article systematically analyzes the core reasons for suboptimal results and provides practical mitigation strategies to help improve the disinfection success rate, intended for quick clinical reference. Chlorhexidine [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/\" \/>\n<meta property=\"og:site_name\" content=\"CHG IPA APPLICATOR\" \/>\n<meta property=\"article:published_time\" content=\"2025-11-26T07:14:58+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chgswabstick.com\/wp-content\/uploads\/2025\/11\/\u4e3b\u56fe6.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Guanliyuan\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Guanliyuan\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/\",\"url\":\"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/\",\"name\":\"Inadequate Disinfection with CHG Applicators? 3 Core Reasons and Mitigation Strategies - CHG IPA APPLICATOR\",\"isPartOf\":{\"@id\":\"https:\/\/chgswabstick.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/chgswabstick.com\/wp-content\/uploads\/2025\/11\/\u4e3b\u56fe6.webp\",\"datePublished\":\"2025-11-26T07:14:58+00:00\",\"author\":{\"@id\":\"https:\/\/chgswabstick.com\/#\/schema\/person\/792f22828d8a8ee0a6952781867adb73\"},\"breadcrumb\":{\"@id\":\"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/#primaryimage\",\"url\":\"https:\/\/chgswabstick.com\/wp-content\/uploads\/2025\/11\/\u4e3b\u56fe6.webp\",\"contentUrl\":\"https:\/\/chgswabstick.com\/wp-content\/uploads\/2025\/11\/\u4e3b\u56fe6.webp\",\"width\":800,\"height\":800},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/chgswabstick.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Inadequate Disinfection with CHG Applicators? 3 Core Reasons and Mitigation Strategies\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/chgswabstick.com\/#website\",\"url\":\"https:\/\/chgswabstick.com\/\",\"name\":\"CHG IPA APPLICATOR\",\"description\":\"CHG Applicator Manufacturer | Chlorhexidine Swab Stick &amp; Chlorhexidine Applicator for Medical Skin Disinfection\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/chgswabstick.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/chgswabstick.com\/#\/schema\/person\/792f22828d8a8ee0a6952781867adb73\",\"name\":\"Guanliyuan\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/chgswabstick.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/91b86f5c2f2c6e2cf8bfe75b17f7bd11895fa216fb48fcdad9df3b9eddaf0d88?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/91b86f5c2f2c6e2cf8bfe75b17f7bd11895fa216fb48fcdad9df3b9eddaf0d88?s=96&d=mm&r=g\",\"caption\":\"Guanliyuan\"},\"sameAs\":[\"http:\/\/chgswabstick.com\"],\"url\":\"https:\/\/chgswabstick.com\/author\/guanliyuan\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Inadequate Disinfection with CHG Applicators? 3 Core Reasons and Mitigation Strategies - CHG IPA APPLICATOR","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/","og_locale":"en_US","og_type":"article","og_title":"Inadequate Disinfection with CHG Applicators? 3 Core Reasons and Mitigation Strategies","og_description":"In clinical practice, the standardized use of CHG applicators is crucial for infection prevention. However, instances of inadequate disinfection often stem from a few easily overlooked details. This article systematically analyzes the core reasons for suboptimal results and provides practical mitigation strategies to help improve the disinfection success rate, intended for quick clinical reference. Chlorhexidine [&hellip;]","og_url":"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/","og_site_name":"CHG IPA APPLICATOR","article_published_time":"2025-11-26T07:14:58+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/chgswabstick.com\/wp-content\/uploads\/2025\/11\/\u4e3b\u56fe6.webp","type":"image\/webp"}],"author":"Guanliyuan","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Guanliyuan","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/","url":"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/","name":"Inadequate Disinfection with CHG Applicators? 3 Core Reasons and Mitigation Strategies - CHG IPA APPLICATOR","isPartOf":{"@id":"https:\/\/chgswabstick.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/#primaryimage"},"image":{"@id":"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/#primaryimage"},"thumbnailUrl":"https:\/\/chgswabstick.com\/wp-content\/uploads\/2025\/11\/\u4e3b\u56fe6.webp","datePublished":"2025-11-26T07:14:58+00:00","author":{"@id":"https:\/\/chgswabstick.com\/#\/schema\/person\/792f22828d8a8ee0a6952781867adb73"},"breadcrumb":{"@id":"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/#primaryimage","url":"https:\/\/chgswabstick.com\/wp-content\/uploads\/2025\/11\/\u4e3b\u56fe6.webp","contentUrl":"https:\/\/chgswabstick.com\/wp-content\/uploads\/2025\/11\/\u4e3b\u56fe6.webp","width":800,"height":800},{"@type":"BreadcrumbList","@id":"https:\/\/chgswabstick.com\/index.php\/2025\/11\/26\/inadequate-disinfection-with-chg-applicators-3-core-reasons-and-mitigation-strategies\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/chgswabstick.com\/"},{"@type":"ListItem","position":2,"name":"Inadequate Disinfection with CHG Applicators? 3 Core Reasons and Mitigation Strategies"}]},{"@type":"WebSite","@id":"https:\/\/chgswabstick.com\/#website","url":"https:\/\/chgswabstick.com\/","name":"CHG IPA APPLICATOR","description":"CHG Applicator Manufacturer | Chlorhexidine Swab Stick &amp; Chlorhexidine Applicator for Medical Skin Disinfection","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chgswabstick.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/chgswabstick.com\/#\/schema\/person\/792f22828d8a8ee0a6952781867adb73","name":"Guanliyuan","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/chgswabstick.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/91b86f5c2f2c6e2cf8bfe75b17f7bd11895fa216fb48fcdad9df3b9eddaf0d88?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/91b86f5c2f2c6e2cf8bfe75b17f7bd11895fa216fb48fcdad9df3b9eddaf0d88?s=96&d=mm&r=g","caption":"Guanliyuan"},"sameAs":["http:\/\/chgswabstick.com"],"url":"https:\/\/chgswabstick.com\/author\/guanliyuan\/"}]}},"_links":{"self":[{"href":"https:\/\/chgswabstick.com\/index.php\/wp-json\/wp\/v2\/posts\/157","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chgswabstick.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/chgswabstick.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/chgswabstick.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chgswabstick.com\/index.php\/wp-json\/wp\/v2\/comments?post=157"}],"version-history":[{"count":1,"href":"https:\/\/chgswabstick.com\/index.php\/wp-json\/wp\/v2\/posts\/157\/revisions"}],"predecessor-version":[{"id":164,"href":"https:\/\/chgswabstick.com\/index.php\/wp-json\/wp\/v2\/posts\/157\/revisions\/164"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chgswabstick.com\/index.php\/wp-json\/wp\/v2\/media\/163"}],"wp:attachment":[{"href":"https:\/\/chgswabstick.com\/index.php\/wp-json\/wp\/v2\/media?parent=157"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/chgswabstick.com\/index.php\/wp-json\/wp\/v2\/categories?post=157"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/chgswabstick.com\/index.php\/wp-json\/wp\/v2\/tags?post=157"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}